Huawei S6730-H24X4Y4Cswitch 24*10GE SFP+ ports, 4*GE/10GE/25GE SFP28 ports, 4*40GE/100GE QSFP28 ports, 2 hot swappable AC/DC power supplies, without power model equipped
Item |
s6730-h24x4y4c |
Memory |
4 GB |
Flash memory |
2 GB in total. To view the available flash memory size, run the display version command. |
Console port |
RJ45 |
Eth Management port |
RJ45 |
USB |
Supported |
RTC |
Supported |
RPS |
Not supported |
Service port surge protection [kV] |
– |
Power supply surge protection [kV] |
Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode |
Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode |
|
Types of fans |
Built-in |
Heat dissipation |
Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction |
Air flows in from the left side and front panel, and exhausts from the right side. |
PoE |
Not supported |
Certification |
EMC certification |
Safety certification |
|
Manufacturing certification |
|
Number of card slots |
0 |
Number of power slots |
2 |
Number of fans |
3 |
Redundant power supply |
1+1 |
AC and DC power can be used together. |
|
Long-term operating temperature [°C(°F)] |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] |
Not supported |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
|
The operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module. |
|
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
Pluggable power supply |
Rated input voltage [V] |
AC input: 100 V AC to 240 V AC, 50/60 Hz |
High-Voltage DC input: 240 V DC |
|
DC input: -48 V DC to -60 V DC |
|
Input voltage range [V] |
AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz |
High-Voltage DC input: 190 V DC to 290 V DC |
|
DC input: -38.4 V DC to -72 V DC |
|
Maximum input current [A] |
300 W AC: 4 A |
260 W DC: 10 A |
|
Weight without packaging [kg(lb)] |
3.4 kg (7.5 lb) |
Weight with packaging [kg(lb)] |
4.65 kg (10.25 lb) |
Typical power consumption [W] |
186 W |
Typical heat dissipation [BTU/hour] |
634.65 BTU/hour |
Maximum power consumption [W] |
253 W |
Maximum heat dissipation [BTU/hour] |
863.26 BTU/hour |
MTBF [year] |
54.68 year |
MTTR [hour] |
2 hour |
Availability |
>0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
64.5 dB(A) |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.4 in. x 9.1 in.) |
|
Dimensions with packaging (H x W x D) [mm(in.)] |
115 mm × 545 mm × 360 mm (4.53 in. x 21.46 in. x 14.17 in.) |
Chassis height [U] |